Superbubble 1 in (25 mm): R-37 Walls and R-48 Roofs
Superbubble is the thickest bubble insulation IIP makes: 1 in (25 mm) of air cells between reflective faces, in foil/foil or foil/white. It is built for metal-building walls and roofs where you want more performance from a reflective system.
What the numbers mean
Reflective insulation is rated as part of an assembly, because the enclosed air spaces do much of the work. In IIP’s specification build-ups, each Superbubble layer counts as R-3.5. Two layers with the reflective air spaces shown reach the system values below, calculated per the ASHRAE Handbook of Fundamentals (Chapter 26, Table 3) and ASTM C1224.
| Assembly | Build-up, outside to inside | System value |
|---|---|---|
| Metal building wall | Metal cladding · 1 in (25 mm) air space · Superbubble (R-3.5) · 6 in (152 mm) reflective dead air space (R-30) · Superbubble (R-3.5) · 1-1/4 in (32 mm) air space · thermal break | R-37 |
| Metal roof | Metal roof · 1-1/4 in (32 mm) air space · Superbubble foil/foil (R-3.5) · 8 in (203 mm) reflective dead air space (R-44) · Superbubble foil/white (R-3.5) · 1 in (25 mm) air space | R-48 |
| Wall behind ventilated siding | Wood siding · furring gap · Superbubble (R-5) · building paper · sheathing | R-5 layer |
Superbubble vs double bubble
In the same two-layer metal wall build-up, Superbubble layers count as R-3.5 each for a system R-37, compared with R-2 per layer and R-34 for IIP double bubble.
Facings
- Foil/foil: reflective on both sides, for cavities with air spaces on each face.
- Foil/white: a bright interior finish, or the inner thermal break in the roof solution.
How to install
- Fix Superbubble to the outer frame with large-head screws or similar fixings.
- Use spacers to hold the air space between the insulation and the cladding.
- Unroll and fix the second sheet on the C-channels or purlins; add wood furring if needed.
- Overlap sheets by at least 2 in (51 mm) and seal the joints with IIP seaming tape.
- Install the interior lining over the furring channels.
Full installation drawings for the R-37 wall, R-48 roof and ventilated-siding details are available on request.
Questions we get asked
Do I need two layers?
The R-37 wall and R-48 roof systems use two layers with the air spaces shown. A single layer behind ventilated wood siding is rated R-5.
Can I get the installation drawings?
Yes. The R-37 wall, R-48 roof and ventilated-siding drawings are available on request.